Assessment Year 2026
Principal Product Vegetables
NAICS 424480: Fresh Fruit and Vegetable Merchant Wholesalers
SIC 5148: Fresh Fruits and Vegetables
Sales Range $100
M
to 500
M
# of Employees 171
Plant Area 252,000
ft2
Annual Production 80,000,000
lb
Production Hrs. Annual 3,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $579,669 7,590,172
kWh
Electricity Demand $87,309 22,343
kW-mo/yr
Electricity Fees $16,747 -
TOTAL YEARLY COSTS $683,725
RECOMMENDED SAVINGS* $352,802 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7135: Install occupancy sensors $106 $455 $88
1,152
kWh
$18
-
kW-mo/yr
02 2.9114: Use solar heat to make electricty $337,374 $1,306,299 $316,149
4,139,706
kWh
$21,224
-
kW-mo/yr
03 2.2614: Use cooling tower or economizer to replace chiller cooling $15,323 $37,400 $13,899
182,000
kWh
$1,423
-
kW-mo/yr
TOTAL RECOMMENDED $352,802 $1,344,154 $330,137
4,322,858
kWh
$22,666
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs