Assessment Year | 2023 |
---|---|
Principal Product | Precision machined parts |
NAICS | 332721: Precision Turned Product Manufacturing |
SIC | 3452: Bolts, Nuts, Screws, Rivets, and Washers |
Sales Range | $10 M to 50M |
# of Employees | 195 |
Plant Area |
56,000
ft2
|
Annual Production | 84,000,000
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $451,134 | 5,035,524 |
kWh
|
$0.090 |
TOTAL YEARLY COSTS | $451,134 | |||
RECOMMENDED SAVINGS* | $19,091 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $454 | $640 |
$454
5,040
kWh
|
|
02 | 2.9114: Use solar heat to make electricty | $11,383 | $217,770 |
$11,383
126,480
kWh
|
|
03 | 2.2511: Insulate bare equipment | $7,255 | $126 |
$7,255
80,607
kWh
|
|
TOTAL RECOMMENDED | $19,091 | $218,536 |
$19,091
212,127
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs