Assessment Year | 2023 |
---|---|
Principal Product | Water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $1 M to 5M |
# of Employees | 12 |
Plant Area |
164,550
ft2
|
Annual Production | 2,737,500
Tgal
|
Production Hrs. Annual | 8,544
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,065 | 833,940 |
kWh
|
$0.078 |
Electricity Demand | $9,910 | 2,478 |
kW-mo/yr
|
$4.00 |
Electricity Fees | $1,020 | - |
|
- |
TOTAL YEARLY COSTS | $75,996 | |||
RECOMMENDED SAVINGS* | $256,578 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $68,689 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $512 | $375 |
$478
5,980
kWh
|
$34
-
kW-mo/yr
|
- | |
02 | 3.8121: Cover containers to minimize evaporative losses | $187,890 | $1,576,666 | - | - | $187,890 | |
03 | 2.9114: Use solar heat to make electricty | $68,177 | $780,672 |
$59,936
749,199
kWh
|
$8,241
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $256,578 | $2,357,713 |
$60,414
755,179
kWh
|
$8,275
-
kW-mo/yr
|
$187,890 | ||
TOTAL IMPLEMENTED | $68,689 | $781,047 |
$60,414
755,179
kWh
|
$8,275
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs