ITAC Assessment: TP0005
ITAC logo
ITAC Assessment: TP0005
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product Hydrants, Valves and Parts
NAICS
n/a
SIC 3321: Gray and Ductile Iron Foundries
Sales Range $10
M
to 50
M
# of Employees 191
Plant Area
n/a
Annual Production 155,000
pieces
Production Hrs. Annual 7,272
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,894 4,537,515
kWh
Electricity Demand $74,380 9,161
kW-mo/yr
Electricity Fees $(-7,112.0) -
Natural Gas $50,108 15,490
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $12,982 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,097

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $4,894 $88 $3,369
134,818
kWh
$1,525
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,720 - $2,720
92,907
kWh
- -
03 2.4133: Use most efficient type of electric motors $2,348 $4,741 $1,614
64,478
kWh
$734
-
kW-mo/yr
-
04 3.4111: Use closed cycle process to minimize waste water production $1,671 $7,300 - - $1,671
-
Tgal
05 2.4314: Use synthetic lubricant $991 - $512
19,637
kWh
$479
-
kW-mo/yr
-
06 2.7124: Make a practice of turning off lights when not needed $358 - $358
14,361
kWh
- -
TOTAL RECOMMENDED $12,982 $12,129 $8,573
326,201
kWh
$2,738
-
kW-mo/yr
$1,671
-
Tgal
TOTAL IMPLEMENTED $7,097 $12,041 $4,692
171,746
kWh
$734
-
kW-mo/yr
$1,671
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs