| Assessment Year | 1989 |
|---|---|
| Principal Product | HOSPITAL STOCKINGS |
| NAICS |
n/a
|
| SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
| Sales Range | $10 M to 50M |
| # of Employees | 420 |
| Plant Area |
n/a
|
| Annual Production | 570,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $454,187 | 8,754,689 |
kWh
|
$0.052 |
| Natural Gas | $47,453 | 18,373 |
MMBtu
|
$2.58 |
| Fuel Oil #6 | $37,974 | 15,171 |
MMBtu
|
$2.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,343 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $27,359 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #6 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2163: Use minimum steam operating pressure | $4,924 | - | - |
$2,756
-
MMBtu
|
$2,168
-
MMBtu
|
- | |
| 02 | 2.2135: Repair and eliminate steam leaks | $4,213 | $720 | - |
$2,358
-
MMBtu
|
$1,855
-
MMBtu
|
- | |
| 03 | 2.2136: Install / repair insulation on steam lines | $2,450 | $718 | - |
$1,370
-
MMBtu
|
$1,080
-
MMBtu
|
- | |
| 04 | 2.7123: Keep lamps and reflectors clean | $10,766 | $33,188 |
$10,363
199,297
kWh
|
- | - | $403 | |
| 05 | 2.2121: Increase amount of condensate returned | $1,712 | $4,156 | - |
$954
-
MMBtu
|
$758
-
MMBtu
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,977 | $330 |
$8,977
172,626
kWh
|
- | - | - | |
| 07 | 2.2437: Recover waste heat from equipment | $959 | $1,960 | - |
$536
-
MMBtu
|
$423
-
MMBtu
|
- | |
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $556 | - | - |
$479
-
MMBtu
|
$377
-
MMBtu
|
$(-300.0) | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,404 | $4,000 |
$4,404
84,701
kWh
|
- | - | - | |
| 10 | 2.2511: Insulate bare equipment | $123 | $50 | - |
$68
-
MMBtu
|
$55
-
MMBtu
|
- | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $259 | $270 |
$259
4,982
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $39,343 | $45,392 |
$24,003
461,606
kWh
|
$8,521
-
MMBtu
|
$6,716
-
MMBtu
|
$103 | ||
| TOTAL IMPLEMENTED | $27,359 | $9,974 |
$13,381
257,327
kWh
|
$7,985
-
MMBtu
|
$6,293
-
MMBtu
|
$(-300.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #6 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs