| Assessment Year | 1986 |
|---|---|
| Principal Product | SMALL HOUSEHOLD APPLIANCES |
| NAICS |
n/a
|
| SIC | 3634: Electric Housewares and Fans |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
n/a
|
| Annual Production | 900,000
pieces
|
| Production Hrs. Annual | 4,165
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $142,026 | 2,711,899 |
kWh
|
$0.052 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,783 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,171 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.5196: Use small number of high output units instead of many small inefficient units | $3,536 | $815 |
$3,536
67,995
kWh
|
|
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,530 | $9,916 |
$2,530
48,652
kWh
|
|
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $5,837 | $10,750 |
$5,837
112,251
kWh
|
|
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,539 | $2,750 |
$1,539
29,601
kWh
|
|
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $747 | - |
$747
14,361
kWh
|
|
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $335 | $445 |
$335
6,448
kWh
|
|
| 07 | 2.6127: Maintain air filters by cleaning or replacement | $259 | $275 |
$259
4,982
kWh
|
|
| TOTAL RECOMMENDED | $14,783 | $24,951 |
$14,783
284,290
kWh
|
||
| TOTAL IMPLEMENTED | $11,171 | $14,590 |
$11,171
214,829
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs