Assessment Year | 2005 |
---|---|
Principal Product | armored vehicles |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3713: Truck and Bus Bodies |
Sales Range | $10 M to 50M |
# of Employees | 155 |
Plant Area |
145,000
ft2
|
Annual Production | 6,000
pieces
|
Production Hrs. Annual | 7,320
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $193,571 | 2,422,854 |
kWh
|
$0.080 |
Electricity Demand | $66,923 | 9,577 |
kW-mo/yr
|
$6.99 |
Electricity Fees | $9,951 | - |
|
- |
Natural Gas | $36,568 | 4,299 |
MMBtu
|
$8.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $89,311 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $29,692 | $1,000 |
$21,605
327,352
kWh
|
$8,087
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $45,200 | $25,500 |
$31,750
481,457
kWh
|
$13,450
-
kW-mo/yr
|
- | |
03 | 2.8121: Apply for tax-free status for energy purchases | $7,870 | $(-7,870.0) | - | - | $7,870 | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,691 | $5,500 |
$4,298
65,127
kWh
|
$1,393
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $502 | $616 |
$404
6,132
kWh
|
$98
-
kW-mo/yr
|
- | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $356 | - |
$88
1,338
kWh
|
$268
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $89,311 | $24,746 |
$58,145
881,406
kWh
|
$23,296
-
kW-mo/yr
|
$7,870 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs