| Assessment Year | 2005 |
|---|---|
| Principal Product | Wheat Flour |
| NAICS | 311211: Flour Milling |
| SIC | 2041: Flour and Other Grain Mill Products |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
800,000
ft2
|
| Annual Production | 781,000,000
lb
|
| Production Hrs. Annual | 8,520
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,351,989 | 28,631,474 |
kWh
|
$0.047 |
| Electricity Demand | $261,379 | 52,910 |
kW-mo/yr
|
$4.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,810 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,225 | $410 |
$5,700
120,760
kWh
|
$525
-
kW-mo/yr
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $4,585 | $125 |
$4,200
88,980
kWh
|
$385
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,640 | - |
$1,500
31,900
kWh
|
$140
-
kW-mo/yr
|
|
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $325 | - |
$265
5,606
kWh
|
$60
-
kW-mo/yr
|
|
| 05 | 2.6218: Turn off equipment when not in use | $175 | - |
$175
3,700
kWh
|
- | |
| TOTAL RECOMMENDED | $12,950 | $535 |
$11,840
250,946
kWh
|
$1,110
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $10,810 | $535 |
$9,900
209,740
kWh
|
$910
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs