Assessment Year | 2016 |
---|---|
Principal Product | Specialty Metal Products |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 56 |
Plant Area |
38,000
ft2
|
Annual Production | 623,000
pieces
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,128 | 1,217,840 |
kWh
|
$0.053 |
Electricity Demand | $30,122 | 2,837 |
kW-mo/yr
|
$10.62 |
Electricity Fees | $3,648 | - |
|
- |
Natural Gas | $4,730 | 855 |
MMBtu
|
$5.53 |
TOTAL YEARLY COSTS | $103,628 | |||
RECOMMENDED SAVINGS* | $18,321 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,145 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1161: Eliminate/reduce an operation | $1,752 | - |
$966
18,060
kWh
|
$786
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $450 | - |
$450
8,405
kWh
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $484 | $164 |
$141
2,637
kWh
|
$38
-
kW-mo/yr
|
- | $235 | $70 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $153 | $150 |
$153
2,856
kWh
|
- | - | - | - | |
05 | 3.1161: Eliminate/reduce an operation | $880 | $960 |
$(-10.0)
(-188)
kWh
|
$(-115.0)
-
kW-mo/yr
|
- | $417 | $588 | |
06 | 2.7314: Reduce ventilation air | $846 | $880 |
$200
3,736
kWh
|
- |
$646
-
MMBtu
|
- | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $189 | $332 |
$189
3,534
kWh
|
- | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,567 | $25,530 |
$6,213
116,137
kWh
|
$7,251
-
kW-mo/yr
|
- | $1,379 | $(-1,276.0) | |
TOTAL RECOMMENDED | $18,321 | $28,016 |
$8,302
155,177
kWh
|
$7,960
-
kW-mo/yr
|
$646
-
MMBtu
|
$2,031 | $(-618.0) | ||
TOTAL IMPLEMENTED | $16,145 | $26,176 |
$7,662
143,224
kWh
|
$8,075
-
kW-mo/yr
|
- | $1,614 | $(-1,206.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs