Assessment Year 2016
Principal Product Specialty Metal Products
NAICS 332710: Machine Shops
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 56
Plant Area 38,000
ft2
Annual Production 623,000
pieces
Production Hrs. Annual 2,040
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $65,128 1,217,840
kWh
Electricity Demand $30,122 2,837
kW-mo/yr
Electricity Fees $3,648 -
Natural Gas $4,730 855
MMBtu
TOTAL YEARLY COSTS $103,628
RECOMMENDED SAVINGS* $18,321 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,145

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 3.1161: Eliminate/reduce an operation $1,752 - $966
18,060
kWh
$786
-
kW-mo/yr
- - -
02 2.4231: Reduce the pressure of compressed air to the minimum required $450 - $450
8,405
kWh
- - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $484 $164 $141
2,637
kWh
$38
-
kW-mo/yr
- $235 $70
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $153 $150 $153
2,856
kWh
- - - -
05 3.1161: Eliminate/reduce an operation $880 $960 $(-10.0)
(-188)
kWh
$(-115.0)
-
kW-mo/yr
- $417 $588
06 2.7314: Reduce ventilation air $846 $880 $200
3,736
kWh
- $646
-
MMBtu
- -
07 2.6211: Conserve energy by efficient use of vending machines $189 $332 $189
3,534
kWh
- - - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $13,567 $25,530 $6,213
116,137
kWh
$7,251
-
kW-mo/yr
- $1,379 $(-1,276.0)
TOTAL RECOMMENDED $18,321 $28,016 $8,302
155,177
kWh
$7,960
-
kW-mo/yr
$646
-
MMBtu
$2,031 $(-618.0)
TOTAL IMPLEMENTED $16,145 $26,176 $7,662
143,224
kWh
$8,075
-
kW-mo/yr
- $1,614 $(-1,206.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs