| Assessment Year | 2026 |
|---|---|
| Principal Product | Wine |
| NAICS | 312130: Wineries |
| SIC | 2084: Wines, Brandy, and Brandy Spirits |
| Sales Range | greater than $500 M |
| # of Employees | 500 |
| Plant Area |
2,500,000
ft2
|
| Annual Production | 15,000,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,796,580 | 17,013,632 |
kWh
|
$0.16 |
| Electricity Demand | $1,145,999 | 39,324 |
kW-mo/yr
|
$29.14 |
| Natural Gas | $257,164 | 12,813 |
MMBtu
|
$20.07 |
| TOTAL YEARLY COSTS | $4,199,743 | |||
| RECOMMENDED SAVINGS* | $2,042,502 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,860 | $1,920 |
$10,860
66,067
kWh
|
- | - | - | - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $41,007 | $1,080 |
$28,381
172,635
kWh
|
$12,626
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $12,481 | - |
$12,481
75,921
kWh
|
- | - | - | - | |
| 04 | 2.7226: Use computer programs to optimize hvac performance | $21,145 | $5,099 |
$21,145
128,619
kWh
|
- | - | - | - | |
| 05 | 2.1224: Replace boiler | $77,010 | $244,130 | - | - |
$6,210
-
MMBtu
|
$(-1,200.0) | $72,000 | |
| 06 | 2.2511: Insulate bare equipment | $818 | $3,408 |
$818
4,977
kWh
|
- | - | - | - | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $46,662 | $211,375 |
$44,988
273,648
kWh
|
- |
$1,674
-
MMBtu
|
- | - | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,070 | $30,818 |
$6,070
36,922
kWh
|
- | - | - | - | |
| 09 | 2.9114: Use solar heat to make electricty | $1,826,449 | $12,059,302 |
$1,826,449
11,109,785
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $2,042,502 | $12,557,132 |
$1,951,192
11,868,574
kWh
|
$12,626
-
kW-mo/yr
|
$7,884
-
MMBtu
|
$(-1,200.0) | $72,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs