Assessment Year | 2025 |
---|---|
Principal Product | Plastic Packaging |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2656: Sanitary Food Containers, Except Folding |
Sales Range | $100 M to 500M |
# of Employees | 382 |
Plant Area |
260,000
ft2
|
Annual Production | 147,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,532,523 | 19,072,000 |
kWh
|
$0.13 |
Electricity Demand | $634,792 | 33,396 |
kW-mo/yr
|
$19.01 |
Natural Gas | $1,191 | 523 |
MMBtu
|
$2.28 |
TOTAL YEARLY COSTS | $3,168,506 | |||
RECOMMENDED SAVINGS* | $645,243 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $33,495 | - |
$35,895
270,288
kWh
|
- | $(-2,400.0) | |
02 | 2.6218: Turn off equipment when not in use | $71,540 | - |
$71,540
538,708
kWh
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $62,779 | $13,540 |
$62,779
472,727
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $749 | $311 |
$623
4,697
kWh
|
$126
-
kW-mo/yr
|
- | |
05 | 2.6218: Turn off equipment when not in use | $32,229 | $20,192 |
$32,229
242,683
kWh
|
- | - | |
06 | 2.6218: Turn off equipment when not in use | $2,986 | $2,376 |
$2,986
22,482
kWh
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $154,683 | $168,414 |
$129,293
973,564
kWh
|
$25,390
-
kW-mo/yr
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,397 | $47,899 |
$27,397
206,304
kWh
|
- | - | |
09 | 2.9114: Use solar heat to make electricty | $259,385 | $1,308,722 |
$259,385
1,953,197
kWh
|
- | - | |
TOTAL RECOMMENDED | $645,243 | $1,561,454 |
$622,127
4,684,650
kWh
|
$25,516
-
kW-mo/yr
|
$(-2,400.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs