ITAC Assessment: SF0541
ITAC logo
ITAC Assessment: SF0541
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2019
Principal Product Candy
NAICS 311352: Confectionery Manufacturing from Purchased Chocolate
SIC 2067: Chewing Gum
Sales Range $50
M
to 100
M
# of Employees 125
Plant Area 300,000
ft2
Annual Production 23,000,000
lb
Production Hrs. Annual 5,775
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $765,795 9,993,509
kWh
Electricity Demand $323,718 18,204
kW-mo/yr
Natural Gas $243,635 44,378
MMBtu
TOTAL YEARLY COSTS $1,333,148
RECOMMENDED SAVINGS* $197,020 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $147,604

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $16,964 $5,000 $17,972
234,626
kWh
- - $(-1,008.0) -
02 2.7224: Reduce space conditioning during non-working hours $3,815 $1,514 $3,100
40,467
kWh
- $715
-
MMBtu
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $21,931 $15,969 $14,795
193,146
kWh
$7,136
-
kW-mo/yr
- - -
04 2.4313: Provide proper maintenance of motor driven equipment $1,697 $1,327 $1,697
21,158
kWh
- - - -
05 2.2135: Repair and eliminate steam leaks $7,042 $7,678 - - $7,042
-
MMBtu
- -
06 2.4322: Use or replace with energy efficient substitutes $261 $578 $261
3,410
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $50,599 $153,278 $30,717
401,007
kWh
$15,286
-
kW-mo/yr
- $4,688 $(-92.0)
08 2.2511: Insulate bare equipment $2,727 $8,304 $923
12,055
kWh
- $1,804
-
MMBtu
- -
09 2.4322: Use or replace with energy efficient substitutes $36,428 $115,019 $12,548
163,807
kWh
$6,052
-
kW-mo/yr
$17,828
-
MMBtu
- -
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $6,140 $26,538 $6,140
80,155
kWh
- - - -
11 2.2614: Use cooling tower or economizer to replace chiller cooling $49,416 $245,226 $35,548
464,077
kWh
$13,868
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $197,020 $580,431 $123,701
1,613,908
kWh
$42,342
-
kW-mo/yr
$27,389
-
MMBtu
$3,680 $(-92.0)
TOTAL IMPLEMENTED $147,604 $335,205 $88,153
1,149,831
kWh
$28,474
-
kW-mo/yr
$27,389
-
MMBtu
$3,680 $(-92.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs