| Assessment Year | 2001 |
|---|---|
| Principal Product | calf milk replacer |
| NAICS |
n/a
|
| SIC | 2023: Dry, Condensed, and Evaporated Dairy Products |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
76,000
ft2
|
| Annual Production | 17,000
ton
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,061 | 883,888 |
kWh
|
$0.11 |
| Natural Gas | $2,530 | 248 |
MMBtu
|
$10.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,877 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,182 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,206 | - |
$1,206
12,843
kWh
|
- | |
| 02 | 2.2314: Replace heat treating oven with more efficient unit | $5,816 | $5,705 |
$5,816
(-21,804)
kWh
|
- | |
| 03 | 2.2611: Moderate cooling tower outlet temperature | $415 | $406 |
$415
3,749
kWh
|
- | |
| 04 | 2.7132: Install timers on light switches in little used areas | $529 | $840 |
$529
4,774
kWh
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,695 | $11,140 |
$1,695
15,312
kWh
|
- | |
| 06 | 4.132: Purchase new equipment to reduce material use / cost | $14,216 | $507 | - | $14,216 | |
| TOTAL RECOMMENDED | $23,877 | $18,598 |
$9,661
14,874
kWh
|
$14,216 | ||
| TOTAL IMPLEMENTED | $22,182 | $7,458 |
$7,966
(-438)
kWh
|
$14,216 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs