Assessment Year 1997
Principal Product Corrugated Containers
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area 114,000
ft2
Annual Production 120,000
thousand feet
Production Hrs. Annual 4,160
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $63,393 781,067
kWh
Electricity Demand $12,412 2,997
kW-mo/yr
Natural Gas $1,682 271
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,992 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,956

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.4133: Use most efficient type of electric motors $262 $623 $228
2,931
kWh
$34
-
kW-mo/yr
-
02 2.7144: Install spectral reflectors / delamp $756 $1,650 $625
7,620
kWh
$131
-
kW-mo/yr
-
03 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $2,539 $4,000 $2,213
27,257
kWh
$326
-
kW-mo/yr
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $242 $168 $211
2,638
kWh
$31
-
kW-mo/yr
-
05 2.4239: Eliminate or reduce compressed air usage $302 $124 $302
3,810
kWh
- -
06 2.4239: Eliminate or reduce compressed air usage $1,497 $3,347 $1,305
16,120
kWh
$192
-
kW-mo/yr
-
07 3.5313: Increase amount of waste recovered for resale $1,394 - - - $1,394
-
lb
TOTAL RECOMMENDED $6,992 $9,912 $4,884
60,376
kWh
$714
-
kW-mo/yr
$1,394
-
lb
TOTAL IMPLEMENTED $2,956 $2,565 $1,366
16,999
kWh
$196
-
kW-mo/yr
$1,394
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings