| Assessment Year | 1997 |
|---|---|
| Principal Product | Fiber Reinforced Composites |
| NAICS |
n/a
|
| SIC | 3087: Custom Compounding of Purchased Plastics Resins |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
93,000
ft2
|
| Annual Production | 3,456,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $104,299 | 1,715,416 |
kWh
|
$0.061 |
| Electricity Demand | $54,187 | 4,329 |
kW-mo/yr
|
$12.52 |
| Natural Gas | $914 | 102 |
MMBtu
|
$8.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $129,776 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $41,896 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,967 | $32,700 |
$12,164
200,176
kWh
|
$5,803
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $665 | $576 |
$461
7,620
kWh
|
$204
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $2,278 | - |
$2,278
37,515
kWh
|
- | - | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $899 | - |
$632
10,551
kWh
|
$267
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $1,928 | $6,792 |
$1,307
21,395
kWh
|
$621
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.2511: Insulate bare equipment | $1,544 | $480 |
$1,544
25,498
kWh
|
- | - | - | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,220 | $1,475 |
$1,542
25,498
kWh
|
$678
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.7135: Install occupancy sensors | $204 | $224 |
$93
1,465
kWh
|
$111
-
kW-mo/yr
|
- | - | - | |
| 09 | 4.122: Develop standard procedures to improve internal yields | $15,090 | - | - | - | - | - | $15,090 | |
| 10 | 3.5313: Increase amount of waste recovered for resale | $55,781 | - | - | - |
$55,781
-
lb
|
- | - | |
| 11 | 3.2172: Use automatic cleaning equipment | $31,200 | $76,760 | - | - | - | $31,200 | - | |
| TOTAL RECOMMENDED | $129,776 | $119,007 |
$20,021
329,718
kWh
|
$7,684
-
kW-mo/yr
|
$55,781
-
lb
|
$31,200 | $15,090 | ||
| TOTAL IMPLEMENTED | $41,896 | $42,247 |
$19,389
319,167
kWh
|
$7,417
-
kW-mo/yr
|
- | - | $15,090 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs