ITAC Assessment: SF0100
ITAC logo
ITAC Assessment: SF0100
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Garment Dyeing
NAICS
n/a
SIC 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing)
Sales Range $1
M
to 5
M
# of Employees 45
Plant Area 30,000
ft2
Annual Production 2,300,000
lb
Production Hrs. Annual 6,448
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $39,427 432,884
kWh
Electricity Demand $3,952 949
kW-mo/yr
Natural Gas $146,881 60,591
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $94,847 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
01 2.4133: Use most efficient type of electric motors $275 $253 $253
2,638
kWh
$22
-
kW-mo/yr
- - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,710 $5,640 $1,519
16,706
kWh
$191
-
kW-mo/yr
- - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $303 $720 $279
2,931
kWh
$24
-
kW-mo/yr
- - -
04 2.1243: Use heat from boiler blowdown to preheat boiler feed water $4,132 $8,500 - - $4,132
-
MMBtu
- -
05 2.2136: Install / repair insulation on steam lines $970 $1,183 - - $970
-
MMBtu
- -
06 3.4113: Treat and reuse rinse waters $87,457 $173,000 - - - $47,526
-
Tgal
$39,931
-
Tgal
TOTAL RECOMMENDED $94,847 $189,296 $2,051
22,275
kWh
$237
-
kW-mo/yr
$5,102
-
MMBtu
$47,526
-
Tgal
$39,931
-
Tgal
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs