Assessment Year | 1994 |
---|---|
Principal Product | Candy |
NAICS |
n/a
|
SIC | 2064: Candy and Other Confectionery Products |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
160,000
ft2
|
Annual Production | 35,000,000
lb
|
Production Hrs. Annual | 4,358
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $374,011 | 3,458,675 |
kWh
|
$0.11 |
Natural Gas | $401,351 | 103,532 |
MMBtu
|
$3.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $339,012 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,357 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $16,431 | $11,437 |
$16,431
152,110
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,920 | $9,089 |
$6,920
64,185
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $3,335 | $1,851 |
$3,335
30,774
kWh
|
- | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $7,006 | - | - |
$7,006
-
MMBtu
|
- | |
05 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $305,320 | $1,140,000 | - | - | $305,320 | |
TOTAL RECOMMENDED | $339,012 | $1,162,377 |
$26,686
247,069
kWh
|
$7,006
-
MMBtu
|
$305,320 | ||
TOTAL IMPLEMENTED | $30,357 | $20,526 |
$23,351
216,295
kWh
|
$7,006
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs