| Assessment Year | 1993 |
|---|---|
| Principal Product | Custom Molded Plastics |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 650 |
| Plant Area |
96,000
ft2
|
| Annual Production | 4,800
ton
|
| Production Hrs. Annual | 7,056
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,088,250 | 11,963,072 |
kWh
|
$0.091 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $187,436 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $107,378 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $80,058 | $180,000 |
$80,058
-
kWh
|
|
| 02 | 2.2511: Insulate bare equipment | $71,048 | $21,073 |
$71,048
781,067
kWh
|
|
| 03 | 2.2511: Insulate bare equipment | $6,622 | $1,988 |
$6,622
72,685
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $22,511 | $12,625 |
$22,511
247,362
kWh
|
|
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,025 | $900 |
$2,025
27,843
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,172 | $5,236 |
$5,172
56,858
kWh
|
|
| TOTAL RECOMMENDED | $187,436 | $221,822 |
$187,436
1,185,815
kWh
|
||
| TOTAL IMPLEMENTED | $107,378 | $41,822 |
$107,378
1,185,815
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs