Assessment Year 2026
Principal Product metal heat treating services
NAICS 332811: Metal Heat Treating
SIC 3398: Metal Heat Treating
Sales Range $1
M
to 5
M
# of Employees 15
Plant Area 28,000
ft2
Annual Production 2,000,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $26,409 170,954
kWh
Electricity Demand $37,184 878
kW-mo/yr
Natural Gas $186,013 17,066
MMBtu
TOTAL YEARLY COSTS $249,606
RECOMMENDED SAVINGS* $38,610 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $24,744 $29,547 $8,431
54,570
kWh
$16,313
-
kW-mo/yr
-
02 2.3141: Use battery storage for demand control $8,871 $583 $(-702.9)
(-4,549)
kWh
$9,574
-
kW-mo/yr
-
03 2.1121: Use insulation in furnaces to facilitate heating / cooling $1,254 $2,437 - - $1,254
-
MMBtu
04 2.4133: Use most efficient type of electric motors $236 $1,823 $134
870
kWh
$101
-
kW-mo/yr
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $290 - $290
1,877
kWh
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $270 $254 $154
996
kWh
$116
-
kW-mo/yr
-
07 2.3134: Shift from daytime to nighttime operation $2,946 $3,570 $1,526
9,880
kWh
$1,420
-
kW-mo/yr
-
TOTAL RECOMMENDED $38,610 $38,214 $9,832
63,644
kWh
$27,524
-
kW-mo/yr
$1,254
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs