Assessment Year | 2025 |
---|---|
Principal Product | Packaging |
NAICS | 423910: Sporting and Recreational Goods and Supplies Merchant Wholesalers |
SIC | 4225: General Warehousing and Storage |
Sales Range | greater than $500 M |
# of Employees | 65 |
Plant Area |
289,407
ft2
|
Annual Production | 277,862
units
|
Production Hrs. Annual | 3,125
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,457 | 327,932 |
kWh
|
$0.25 |
Electricity Demand | $24,334 | 1,416 |
kW-mo/yr
|
$17.19 |
Electricity Fees | $2,741 | - |
|
- |
LPG | $15,691 | 178 |
MMBtu
|
$88.24 |
TOTAL YEARLY COSTS | $125,223 | |||
RECOMMENDED SAVINGS* | $101,682 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $72,797 | $103,994 |
$56,716
225,602
kWh
|
$16,080
-
kW-mo/yr
|
- | |
02 | 2.3141: Use battery storage for demand control | $2,541 | $1,352 |
$(-2,551.0)
(-10,147)
kWh
|
$5,092
-
kW-mo/yr
|
- | |
03 | 2.3132: Recharge batteries on during off-peak demand periods | $3,996 | - | - |
$3,996
-
kW-mo/yr
|
- | |
04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $14,911 | $23,188 |
$(-780.0)
(-3,103)
kWh
|
- |
$15,691
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,033 | $9,226 |
$5,333
21,214
kWh
|
$700
-
kW-mo/yr
|
- | |
06 | 2.7224: Reduce space conditioning during non-working hours | $1,404 | - |
$1,298
5,163
kWh
|
$107
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $101,682 | $137,760 |
$60,017
238,730
kWh
|
$25,974
-
kW-mo/yr
|
$15,691
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs