| Assessment Year | 2021 |
|---|---|
| Principal Product | Beer |
| NAICS | 312120: Breweries |
| SIC | 2082: Malt Beverages |
| Sales Range | $5 M to 10M |
| # of Employees | 52 |
| Plant Area |
13,850
ft2
|
| Annual Production | 85
Tgal
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,189 | 75,628 |
kWh
|
$0.20 |
| Electricity Demand | $965 | 225 |
kW-mo/yr
|
$4.30 |
| Electricity Fees | $3,608 | - |
|
- |
| TOTAL YEARLY COSTS | $19,762 | |||
| RECOMMENDED SAVINGS* | $5,235 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,235 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7425: Clean or color roof to reduce solar load | $4,310 | $6,942 |
$4,095
20,392
kWh
|
$215
-
kW-mo/yr
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $540 | - |
$540
2,688
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $385 | $1,182 |
$325
1,616
kWh
|
$60
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $5,235 | $8,124 |
$4,960
24,696
kWh
|
$275
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $5,235 | $8,124 |
$4,960
24,696
kWh
|
$275
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs