Assessment Year | 2021 |
---|---|
Principal Product | Aircraft Equipment and Parts |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 391 |
Plant Area |
115,600
ft2
|
Annual Production | 17,000
units
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $294,745 | 5,438,808 |
kWh
|
$0.054 |
Electricity Demand | $105,554 | 6,152 |
kW-mo/yr
|
$17.16 |
Electricity Fees | $10,120 | - |
|
- |
TOTAL YEARLY COSTS | $410,419 | |||
RECOMMENDED SAVINGS* | $10,804 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $804 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,289 | - |
$1,289
23,785
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $2,006 | $2,850 |
$1,059
19,533
kWh
|
$947
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,962 | $5,000 |
$1,035
19,100
kWh
|
$927
-
kW-mo/yr
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,760 | $1,855 |
$883
16,300
kWh
|
$877
-
kW-mo/yr
|
- | |
05 | 2.2625: Chill water to the highest temperature possible | $2,344 | $100 |
$817
15,078
kWh
|
$1,527
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $804 | $1,696 |
$407
7,490
kWh
|
$364
-
kW-mo/yr
|
$33 | |
07 | 2.4133: Use most efficient type of electric motors | $639 | $2,000 |
$337
6,218
kWh
|
$302
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $10,804 | $13,501 |
$5,827
107,504
kWh
|
$4,943
-
kW-mo/yr
|
$33 | ||
TOTAL IMPLEMENTED | $804 | $1,696 |
$407
7,490
kWh
|
$364
-
kW-mo/yr
|
$33 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs