Assessment Year | 2017 |
---|---|
Principal Product | Store Fixtures |
NAICS | 337215: Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood |
Sales Range | $10 M to 50M |
# of Employees | 153 |
Plant Area |
260,000
ft2
|
Annual Production | 15,000
units
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $139,840 | 1,264,026 |
kWh
|
$0.11 |
Electricity Demand | $156,421 | 10,796 |
kW-mo/yr
|
$14.49 |
Electricity Fees | $(-107,254.0) | - |
|
- |
TOTAL YEARLY COSTS | $189,007 | |||
RECOMMENDED SAVINGS* | $49,917 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,705 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,070 | $9,000 |
$17,070
154,342
kWh
|
- | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $11,069 | $31,000 |
$8,355
75,541
kWh
|
$2,714
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,743 | $11,288 |
$6,063
54,827
kWh
|
$680
-
kW-mo/yr
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,078 | $14,300 |
$5,078
45,917
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,740 | $1,500 |
$3,740
33,818
kWh
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,162 | $600 |
$2,162
19,546
kWh
|
- | |
07 | 2.4234: Cool compressor air intake with heat exchanger | $1,935 | $1,833 |
$1,935
17,495
kWh
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $1,153 | $2,288 |
$870
7,870
kWh
|
$283
-
kW-mo/yr
|
|
09 | 2.4239: Eliminate or reduce compressed air usage | $967 | $850 |
$967
8,745
kWh
|
- | |
TOTAL RECOMMENDED | $49,917 | $72,659 |
$46,240
418,101
kWh
|
$3,677
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $22,705 | $46,076 |
$19,028
172,056
kWh
|
$3,677
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs