Assessment Year | 2014 |
---|---|
Principal Product | Mexican Rice Pudding |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2032: Canned Specialties |
Sales Range | $5 M to 10M |
# of Employees | 30 |
Plant Area |
14,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,191 | 548,994 |
kWh
|
$0.079 |
Electricity Demand | $33,885 | 1,703 |
kW-mo/yr
|
$19.90 |
Electricity Fees | $2,221 | - |
|
- |
Natural Gas | $20,318 | 2,798 |
MMBtu
|
$7.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $310 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $4,862 | $5,500 |
$4,142
52,635
kWh
|
$720
-
kW-mo/yr
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $1,726 | $194 |
$1,726
21,928
kWh
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $924 | $3,450 |
$548
6,962
kWh
|
$376
-
kW-mo/yr
|
|
04 | 2.7135: Install occupancy sensors | $609 | $957 |
$609
7,748
kWh
|
- | |
05 | 2.7134: Use photocell controls | $445 | $555 |
$331
4,200
kWh
|
$114
-
kW-mo/yr
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $310 | $200 |
$310
3,933
kWh
|
- | |
TOTAL RECOMMENDED | $8,876 | $10,856 |
$7,666
97,406
kWh
|
$1,210
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $310 | $200 |
$310
3,933
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs