Assessment Year | 2004 |
---|---|
Principal Product | Springs |
NAICS | 332613: Spring Manufacturing |
SIC | 3493: Steel Springs, Except Wire |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
100,000
ft2
|
Annual Production | 637,500
pieces
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,601 | 1,149,039 |
kWh
|
$0.12 |
Electricity Demand | $48,819 | 6,066 |
kW-mo/yr
|
$8.05 |
Natural Gas | $15,218 | 2,069 |
MMBtu
|
$7.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,931 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,484 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $42,981 | $35,875 |
$42,981
367,049
kWh
|
- | - | - | |
02 | 2.1133: Adjust burners for efficient operation | $6,983 | $7,700 | - | - |
$6,983
-
MMBtu
|
- | |
03 | 2.7141: Lower light fixtures in high ceiling areas | $8,464 | $27,829 |
$6,395
54,615
kWh
|
$2,069
-
kW-mo/yr
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $1,104 | $440 |
$74
632
kWh
|
$1,030
-
kW-mo/yr
|
- | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $5,399 | $18,500 | - | - | - |
$5,399
-
lb
|
|
TOTAL RECOMMENDED | $64,931 | $90,344 |
$49,450
422,296
kWh
|
$3,099
-
kW-mo/yr
|
$6,983
-
MMBtu
|
$5,399
-
lb
|
||
TOTAL IMPLEMENTED | $49,484 | $54,815 |
$43,055
367,681
kWh
|
$1,030
-
kW-mo/yr
|
- |
$5,399
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs