ITAC Assessment: SD0214
ITAC logo
ITAC Assessment: SD0214
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product electronic components
NAICS
n/a
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 35,000
ft2
Annual Production 0
pieces
Production Hrs. Annual 4,400
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $67,333 1,305,393
kWh
Electricity Demand $66,845 4,136
kW-mo/yr
Natural Gas $83 10
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $145,989 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,931

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.7144: Install spectral reflectors / delamp $6,221 $5,880 $3,315
64,185
kWh
$2,906
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,699 $10,196 $2,298
44,549
kWh
$2,401
-
kW-mo/yr
- -
03 2.4133: Use most efficient type of electric motors $2,874 $1,100 $1,186
22,860
kWh
$1,688
-
kW-mo/yr
- -
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $38,175 $12,000 $23,871
462,778
kWh
$29,127
-
kW-mo/yr
$(-14,823.0)
-
MMBtu
-
05 3.6192: Use a less expensive method of waste removal $800 - - - - $800
06 3.6192: Use a less expensive method of waste removal $2,832 $1,000 - - - $2,832
07 3.4112: Recovery metals from rinse water(evap., ion exchange, ro, electrolysis, electrodialysis) and reuse rinse water $3,600 $2,300 - - - $3,600
08 4.321: Optimize production lot sizes and inventories $86,788 $60,000 - - - $86,788
TOTAL RECOMMENDED $145,989 $92,476 $30,670
594,372
kWh
$36,122
-
kW-mo/yr
$(-14,823.0)
-
MMBtu
$94,020
TOTAL IMPLEMENTED $11,931 $13,496 $2,298
44,549
kWh
$2,401
-
kW-mo/yr
- $7,232
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs