| Assessment Year | 1999 |
|---|---|
| Principal Product | Processed fish products |
| NAICS |
n/a
|
| SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
| Sales Range | $10 M to 50M |
| # of Employees | 306 |
| Plant Area |
50,000
ft2
|
| Annual Production | 10,517,176
lb
|
| Production Hrs. Annual | 2,175
hrs
|
| Location (State) | Alaska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $186,395 | 2,928,781 |
kWh
|
$0.064 |
| Electricity Demand | $127,512 | 110,640 |
kW-mo/yr
|
$1.15 |
| Electricity Fees | $44,106 | - |
|
- |
| LPG | $8,707 | 698 |
MMBtu
|
$12.47 |
| Fuel Oil #6 | $116,926 | 30,531 |
MMBtu
|
$3.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $360,421 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $202,461 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Personnel Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $13,472 | $27,939 |
$8,925
151,524
kWh
|
$4,547
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $4,055 | $15,400 |
$2,020
34,291
kWh
|
$2,035
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.2136: Install / repair insulation on steam lines | $880 | $700 | - | - |
$880
-
MMBtu
|
- | - | |
| 04 | 2.1224: Replace boiler | $12,100 | - | - | - |
$12,100
-
MMBtu
|
- | - | |
| 05 | 4.441: Install automatic packing equipment | $166,000 | $121,000 | - | - | - | $166,000 | - | |
| 06 | 4.441: Install automatic packing equipment | $90,560 | $64,000 |
$(-180.0)
(-2,931)
kWh
|
$(-160.0)
-
kW-mo/yr
|
- | $90,900 | - | |
| 07 | 4.441: Install automatic packing equipment | $67,400 | $200,000 | - | - | - | $67,400 | - | |
| 08 | 3.4157: Replace water cooling on processes with air cooling | $5,954 | - | - | - | - | - |
$5,954
-
Tgal
|
|
| TOTAL RECOMMENDED | $360,421 | $429,039 |
$10,765
182,884
kWh
|
$6,422
-
kW-mo/yr
|
$12,980
-
MMBtu
|
$324,300 |
$5,954
-
Tgal
|
||
| TOTAL IMPLEMENTED | $202,461 | $165,039 |
$10,945
185,815
kWh
|
$6,582
-
kW-mo/yr
|
$12,980
-
MMBtu
|
$166,000 |
$5,954
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Personnel Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs