Assessment Year | 2019 |
---|---|
Principal Product | Packed Apples |
NAICS | 111331: Apple Orchards |
SIC | 0175: Deciduous Tree Fruits |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
183,000
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,461 | 10,860,340 |
kWh
|
$0.017 |
TOTAL YEARLY COSTS | $185,461 | |||
RECOMMENDED SAVINGS* | $68,101 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,763 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.3128: Utilize other methods to remove contaminants | $27,061 | $33,855 |
$(-1,615.0)
(-65,323)
kWh
|
- | - | $29,000 | $(-324.0) | |
02 | 2.3212: Optimize plant power factor | $31,433 | $68,000 | - | - | $31,433 | - | - | |
03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $4,330 | $1,100 |
$3,947
159,649
kWh
|
$383
-
kW-mo/yr
|
- | - | - | |
04 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $3,139 | $2,013 |
$2,539
102,796
kWh
|
$600
-
kW-mo/yr
|
- | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,138 | $3,275 |
$1,949
78,849
kWh
|
$189
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $68,101 | $108,243 |
$6,820
275,971
kWh
|
$1,172
-
kW-mo/yr
|
$31,433 | $29,000 | $(-324.0) | ||
TOTAL IMPLEMENTED | $35,763 | $69,100 |
$3,947
159,649
kWh
|
$383
-
kW-mo/yr
|
$31,433 | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs