Assessment Year | 2016 |
---|---|
Principal Product | Liquid Packaging |
NAICS | 322219: Other Paperboard Container Manufacturing |
SIC | 2655: Fiber Cans, Tubes, Drums, and Similar Products |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
138,519
ft2
|
Annual Production | 120,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $301,631 | 6,496,460 |
kWh
|
$0.046 |
Electricity Demand | $117,817 | 16,409 |
kW-mo/yr
|
$7.18 |
Electricity Fees | $12,655 | - |
|
- |
Natural Gas | $90,576 | 15,541 |
MMBtu
|
$5.83 |
TOTAL YEARLY COSTS | $522,678 | |||
RECOMMENDED SAVINGS* | $136,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $132,994 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 4.445: Install equipment to move product | $79,123 | $89,654 |
$3,403
73,291
kWh
|
- | $75,720 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $31,062 | $1,969 |
$31,062
668,999
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $22,809 | $23,810 |
$19,468
419,308
kWh
|
$3,341
-
kW-mo/yr
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,199 | $7,215 |
$3,199
68,902
kWh
|
- | - | |
TOTAL RECOMMENDED | $136,193 | $122,648 |
$57,132
1,230,500
kWh
|
$3,341
-
kW-mo/yr
|
$75,720 | ||
TOTAL IMPLEMENTED | $132,994 | $115,433 |
$53,933
1,161,598
kWh
|
$3,341
-
kW-mo/yr
|
$75,720 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs