Assessment Year | 2014 |
---|---|
Principal Product | Plywood |
NAICS | 321211: Hardwood Veneer and Plywood Manufacturing |
SIC | 2435: Hardwood Veneer and Plywood |
Sales Range | $100 M to 500M |
# of Employees | 514 |
Plant Area |
1,000,000
ft2
|
Annual Production | 292,705
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,638,001 | 54,724,000 |
kWh
|
$0.048 |
Electricity Demand | $742,126 | 105,184 |
kW-mo/yr
|
$7.06 |
Electricity Fees | $123,966 | - |
|
- |
Natural Gas | $105,639 | 16,905 |
MMBtu
|
$6.25 |
Wood | $3,040,000 | 1,223,560 |
MMBtu
|
$2.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $347,395 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,183 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Wood Savings |
---|---|---|---|---|---|---|---|
01 | 2.1231: Establish burner maintenance schedule for boilers | $237,276 | $62,840 | - | - |
$237,276
-
MMBtu
|
|
02 | 2.7243: Improve air circulation with destratification fans / other methods | $28,255 | $27,375 |
$22,478
448,032
kWh
|
$5,777
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,466 | $8,550 |
$8,466
168,737
kWh
|
- | - | |
04 | 3.4151: Minimize water usage | $1,003 | - |
$1,003
19,989
kWh
|
- | - | |
05 | 4.652: Replace existing equipment with more suitable substitutes | $11,008 | $9,020 |
$11,008
219,406
kWh
|
- | - | |
06 | 4.652: Replace existing equipment with more suitable substitutes | $40,207 | $13,800 |
$40,207
801,424
kWh
|
- | - | |
07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $21,180 | $10,000 | - |
$21,180
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $347,395 | $131,585 |
$83,162
1,657,588
kWh
|
$26,957
-
kW-mo/yr
|
$237,276
-
MMBtu
|
||
TOTAL IMPLEMENTED | $22,183 | $10,000 |
$1,003
19,989
kWh
|
$21,180
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs