Assessment Year 2003
Principal Product Green Douglas Fir Dimensional Lumber
NAICS 321912: Cut Stock, Resawing Lumber, and Planing
SIC 2421: Sawmills and Planing Mills, General
Sales Range $10
M
to 50
M
# of Employees 60
Plant Area
n/a
Annual Production 33,397
thousand feet
Production Hrs. Annual 4,080
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $119,688 2,929,179
kWh
Electricity Demand $65,627 13,956
kW-mo/yr
Electricity Fees $12,503 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $641,792 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,850

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Increase in Production Savings
01 4.111: Add equipment/ operators to reduce production bottleneck $563,900 $520,900 n/a - - - $191,900 $372,000
02 2.3113: Make ice during off peak hours for cooling $46,744 $15,000 - $18,652
-
kW-mo/yr
$28,092 - -
03 2.6218: Turn off equipment when not in use $14,000 - $14,000
352,000
kWh
- - - -
04 2.4133: Use most efficient type of electric motors $8,080 $10,100 $4,540
114,000
kWh
$3,540
-
kW-mo/yr
- - -
05 2.3212: Optimize plant power factor $5,950 $16,800 n/a - - $5,950 - -
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,770 $665 $1,770
44,480
kWh
- - - -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,348 - $836
21,000
kWh
$512
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $641,792 $563,465 $21,146
531,480
kWh
$22,704
-
kW-mo/yr
$34,042 $191,900 $372,000
TOTAL IMPLEMENTED $9,850 $10,765 $6,310
158,480
kWh
$3,540
-
kW-mo/yr
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs