| Assessment Year | 2000 |
|---|---|
| Principal Product | Particle Board |
| NAICS |
n/a
|
| SIC | 2493: Reconstituted Wood Products |
| Sales Range | $50 M to 100M |
| # of Employees | 190 |
| Plant Area |
250,000
ft2
|
| Annual Production | 190,000
thousand feet
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,575,699 | 66,403,577 |
kWh
|
$0.039 |
| Electricity Demand | $452,914 | 1,278,816 |
kW-mo/yr
|
$0.35 |
| Electricity Fees | $300 | - |
|
- |
| Natural Gas | $834,866 | 265,323 |
MMBtu
|
$3.15 |
| LPG | $26,361 | 3,835 |
MMBtu
|
$6.87 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,343,940 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $538,280 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.126: Install sensors to detect defects | $201,600 | $113,500 | - | - | - | - | $201,600 | - | |
| 02 | 4.421: Modify current incentive program | $337,500 | $66,400 | - | - | - | - | $337,500 | - | |
| 03 | 4.125: | $12,680 | $7,950 | - | - | - | - | $(-16,800.0) | $29,480 | |
| 04 | 4.611: Begin a practice of predictive / preventative maintenance | $324,000 | $4,700 | - | - | - | - | - | $324,000 | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $45,360 | $89,325 |
$38,490
992,087
kWh
|
$6,870
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.1332: Convert combustion equipment to burn natural gas | $13,220 | $94,000 |
$(-700.0)
(-17,878)
kWh
|
$(-360.0)
-
kW-mo/yr
|
$(-12,080.0)
-
MMBtu
|
$26,360
-
MMBtu
|
- | - | |
| 07 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $409,580 | $6,890,000 |
$2,133,310
54,998,242
kWh
|
$322,000
-
kW-mo/yr
|
$(-1,221,000.0)
-
MMBtu
|
- | $(-824,730.0) | - | |
| TOTAL RECOMMENDED | $1,343,940 | $7,265,875 |
$2,171,100
55,972,451
kWh
|
$328,510
-
kW-mo/yr
|
$(-1,233,080.0)
-
MMBtu
|
$26,360
-
MMBtu
|
$(-302,430.0) | $353,480 | ||
| TOTAL IMPLEMENTED | $538,280 | $126,150 | - | - | - | - | $184,800 | $353,480 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs