| Assessment Year | 1990 |
|---|---|
| Principal Product | MOULDINGS, WINDOW FRAMES |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 275 |
| Plant Area |
n/a
|
| Annual Production | 17,000
thousand feet
|
| Production Hrs. Annual | 4,510
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $286,553 | 6,927,315 |
kWh
|
$0.041 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,663 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $23,539 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $20,739 | $26,000 |
$13,509
324,736
kWh
|
$7,230 | |
| 02 | 2.4133: Use most efficient type of electric motors | $695 | $1,366 |
$695
16,999
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $146 | $307 |
$194
4,689
kWh
|
$(-48.0) | |
| 04 | 2.3212: Optimize plant power factor | $2,800 | $6,000 |
$2,800
-
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,283 | $16,250 |
$4,283
104,631
kWh
|
- | |
| TOTAL RECOMMENDED | $28,663 | $49,923 |
$21,481
451,055
kWh
|
$7,182 | ||
| TOTAL IMPLEMENTED | $23,539 | $32,000 |
$16,309
324,736
kWh
|
$7,230 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs