Assessment Year | 1988 |
---|---|
Principal Product | ROASTED COFFEE, SOUPS |
NAICS |
n/a
|
SIC | 2095: Roasted Coffee |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
n/a
|
Annual Production | 11,200,000
lb
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $146,253 | 2,681,125 |
kWh
|
$0.055 |
Natural Gas | $101,244 | 23,587 |
MMBtu
|
$4.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,540 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,160 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $1,003 | $1,200 | - |
$1,003
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $850 | $1,133 |
$868
15,826
kWh
|
- | $(-18.0) | |
03 | 2.2425: Use flue gases to heat process or service water | $16,315 | $41,946 | - |
$16,315
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $307 | $869 |
$253
4,689
kWh
|
- | $54 | |
05 | 2.7492: Use proper thickness of insulation on building envelope | $13,065 | $41,081 | - |
$13,065
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $31,540 | $86,229 |
$1,121
20,515
kWh
|
$30,383
-
MMBtu
|
$36 | ||
TOTAL IMPLEMENTED | $2,160 | $3,202 |
$1,121
20,515
kWh
|
$1,003
-
MMBtu
|
$36 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs