Assessment Year | 2025 |
---|---|
Principal Product | Geothermal Heat Exchangers |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 42 |
Plant Area |
53,000
ft2
|
Annual Production | 65,000
units
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,472 | 883,800 |
kWh
|
$0.057 |
Electricity Demand | $28,876 | 2,831 |
kW-mo/yr
|
$10.20 |
Natural Gas | $27,905 | 8,666 |
MMBtu
|
$3.22 |
TOTAL YEARLY COSTS | $107,253 | |||
RECOMMENDED SAVINGS* | $10,375 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $4,131 | $5,755 | - | - | $4,131 | |
02 | 2.3132: Recharge batteries on during off-peak demand periods | $2,568 | - | - |
$2,568
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $226 | - |
$226
3,972
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,450 | $2,555 |
$3,450
60,528
kWh
|
- | - | |
TOTAL RECOMMENDED | $10,375 | $8,310 |
$3,676
64,500
kWh
|
$2,568
-
kW-mo/yr
|
$4,131 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs