Assessment Year | 2023 |
---|---|
Principal Product | processed wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $5 M to 10M |
# of Employees | 5 |
Plant Area |
350,000
ft2
|
Annual Production | 1,095,000
Tgal
|
Production Hrs. Annual | 2,912
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $452,471 | 5,306,000 |
kWh
|
$0.085 | |
Waste Disposal Costs | |||||
Water Usage | $96,141 | 27,468 |
Tgal
|
$3.50 | |
TOTAL YEARLY COSTS | $548,612 | ||||
RECOMMENDED SAVINGS* | $150,661 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $81,817 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Consumption Savings |
---|---|---|---|---|---|---|
01 | 3.4153: Use counter current rinsing to reduce waste water | $76,727 | $51,456 | - |
$76,727
-
Tgal
|
|
02 | 2.7211: Clean and maintain refrigerant condensers and towers | $172 | $530 |
$172
2,012
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,602 | $1,797 |
$3,602
42,376
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,316 | $3,638 |
$1,316
15,477
kWh
|
- | |
05 | 2.9114: Use solar heat to make electricty | $68,844 | $438,000 |
$68,844
809,928
kWh
|
- | |
TOTAL RECOMMENDED | $150,661 | $495,421 |
$73,934
869,793
kWh
|
$76,727
-
Tgal
|
||
TOTAL IMPLEMENTED | $81,817 | $57,421 |
$5,090
59,865
kWh
|
$76,727
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs