Assessment Year | 1994 |
---|---|
Principal Product | Calcined Petroleum Coke |
NAICS |
n/a
|
SIC | 2999: Products of Petroleum and Coal, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 81 |
Plant Area |
300,000
ft2
|
Annual Production | 600,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $306,459 | 6,383,939 |
kWh
|
$0.048 |
Natural Gas | $3,786,457 | 1,088,811 |
MMBtu
|
$3.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,260,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,451 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $1,247,712 | $4,815,000 |
$1,247,712
25,619,871
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $6,846 | $11,619 |
$6,846
199,590
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,605 | - |
$5,605
163,247
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $467 | $1,920 |
$467
4,103
kWh
|
|
TOTAL RECOMMENDED | $1,260,630 | $4,828,539 |
$1,260,630
25,986,811
kWh
|
||
TOTAL IMPLEMENTED | $12,451 | $11,619 |
$12,451
362,837
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs