Assessment Year 1993
Principal Product Tubular Goods
NAICS
n/a
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 98
Plant Area
n/a
Annual Production 44,607
ton
Production Hrs. Annual 3,432
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $359,829 6,069,461
kWh
Natural Gas $444,829 168,042
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,281 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,517

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,868 - $10,868
367,526
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $6,357 $4,918 $6,357
121,043
kWh
-
03 2.4133: Use most efficient type of electric motors $4,487 $11,785 $4,487
79,719
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,725 $3,693 $1,725
37,808
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $948 $1,079 $948
20,809
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $612 $749 $612
10,844
kWh
-
07 2.1116: Improve combustion control capability $40,284 $190,000 - $40,284
-
MMBtu
TOTAL RECOMMENDED $65,281 $212,224 $24,997
637,749
kWh
$40,284
-
MMBtu
TOTAL IMPLEMENTED $13,517 $21,475 $13,517
259,379
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs