Assessment Year | 1993 |
---|---|
Principal Product | Natural Gas Compressors Packaging and Refurbishing |
NAICS |
n/a
|
SIC | 3563: Air and Gas Compressors |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
52,000
ft2
|
Annual Production | 135
pieces
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,486 | 818,581 |
kWh
|
$0.068 |
Natural Gas | $14,996 | 3,594 |
MMBtu
|
$4.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,415 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,566 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,751 | $4,508 |
$1,751
14,068
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,470 | $18,084 |
$5,470
43,962
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $815 | $1,100 |
$815
4,982
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $379 | $438 | - |
$379
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,415 | $24,130 |
$8,036
63,012
kWh
|
$379
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,566 | $5,608 |
$2,566
19,050
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs