| Assessment Year | 2000 |
|---|---|
| Principal Product | Road Signs |
| NAICS |
n/a
|
| SIC | 3993: Signs and Advertising Specialties |
| Sales Range | $5 M to 10M |
| # of Employees | 38 |
| Plant Area |
27,000
ft2
|
| Annual Production | 750,000
thousand feet
|
| Production Hrs. Annual | 4,004
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,826 | 465,709 |
kWh
|
$0.055 |
| Electricity Demand | $7,533 | 1,934 |
kW-mo/yr
|
$3.90 |
| Electricity Fees | $1,491 | - |
|
- |
| Natural Gas | $8,563 | 1,054 |
MMBtu
|
$8.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,004 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $266 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,380 | $3,814 |
$1,140
20,516
kWh
|
$240
-
kW-mo/yr
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $884 | $2,163 |
$826
12,309
kWh
|
$58
-
kW-mo/yr
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $266 | $200 |
$266
4,689
kWh
|
- | - | - | |
| 04 | 2.4314: Use synthetic lubricant | $158 | $13 |
$99
1,758
kWh
|
$21
-
kW-mo/yr
|
- | $38 | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $1,218 | $150 | - | - |
$1,218
-
MMBtu
|
- | |
| 06 | 2.7224: Reduce space conditioning during non-working hours | $2,218 | $135 |
$2,218
39,859
kWh
|
- | - | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $70 | - |
$70
1,172
kWh
|
- | - | - | |
| 08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $155 | $20 |
$155
2,931
kWh
|
- | - | - | |
| 09 | 2.7224: Reduce space conditioning during non-working hours | $655 | $150 |
$115
2,052
kWh
|
- |
$540
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $7,004 | $6,645 |
$4,889
85,286
kWh
|
$319
-
kW-mo/yr
|
$1,758
-
MMBtu
|
$38 | ||
| TOTAL IMPLEMENTED | $266 | $200 |
$266
4,689
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs