Assessment Year | 1999 |
---|---|
Principal Product | Corrugated Steel Deckin |
NAICS |
n/a
|
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
10,000
ft2
|
Annual Production | 11,650
ton
|
Production Hrs. Annual | 4,335
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $12,334 | 200,469 |
kWh
|
$0.062 |
Electricity Demand | $2,210 | 912 |
kW-mo/yr
|
$2.42 |
Electricity Fees | $2,554 | - |
|
- |
Natural Gas | $812 | 85 |
MMBtu
|
$9.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $141,414 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,532 | $15,691 |
$2,243
36,342
kWh
|
$289
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $87 | $160 |
$87
1,465
kWh
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $495 | $120 |
$495
22,860
kWh
|
- | - | - | |
04 | 4.111: Add equipment/ operators to reduce production bottleneck | $138,300 | $69,125 |
$(-1,700.0)
(-19,930)
kWh
|
- | $(-80,000.0) | $220,000 | |
TOTAL RECOMMENDED | $141,414 | $85,096 |
$1,125
40,737
kWh
|
$289
-
kW-mo/yr
|
$(-80,000.0) | $220,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs