Assessment Year | 2000 |
---|---|
Principal Product | metal coating |
NAICS |
n/a
|
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 68 |
Plant Area |
48,000
ft2
|
Annual Production | 1,750,000
pieces
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,715 | 546,000 |
kWh
|
$0.056 |
Electricity Demand | $12,898 | 1,696 |
kW-mo/yr
|
$7.60 |
Electricity Fees | $325 | - |
|
- |
Natural Gas | $62,259 | 10,556 |
MMBtu
|
$5.90 |
LPG | $108,451 | 11,908 |
MMBtu
|
$9.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,279 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,327 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1113: Reduce combustion air flow to optimum | $12,740 | - | - | - | - |
$12,740
-
MMBtu
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $307 | $468 |
$193
3,517
kWh
|
$113
-
kW-mo/yr
|
$1 | - | - | |
03 | 2.2511: Insulate bare equipment | $1,699 | $574 | - | - | - |
$1,699
-
MMBtu
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $654 | $249 |
$430
7,620
kWh
|
$224
-
kW-mo/yr
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $667 | - |
$502
8,792
kWh
|
$163
-
kW-mo/yr
|
$2 | - | - | |
06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,212 | $9,788 | - | - | - | - |
$3,212
-
lb
|
|
TOTAL RECOMMENDED | $19,279 | $11,079 |
$1,125
19,929
kWh
|
$500
-
kW-mo/yr
|
$3 |
$14,439
-
MMBtu
|
$3,212
-
lb
|
||
TOTAL IMPLEMENTED | $3,327 | $1,291 |
$1,125
19,929
kWh
|
$500
-
kW-mo/yr
|
$3 |
$1,699
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs