| Assessment Year | 2000 |
|---|---|
| Principal Product | Asphalt |
| NAICS |
n/a
|
| SIC | 2951: Asphalt Paving Mixtures and Blocks |
| Sales Range | $5 M to 10M |
| # of Employees | 3 |
| Plant Area |
20,000
ft2
|
| Annual Production | 250,000
ton
|
| Production Hrs. Annual | 925
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,203 | 665,885 |
kWh
|
$0.048 |
| Electricity Demand | $35,445 | 4,641 |
kW-mo/yr
|
$7.64 |
| Electricity Fees | $5,190 | - |
|
- |
| Fuel Oil #2 | $337,849 | 63,091 |
MMBtu
|
$5.35 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $207,296 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Fuel Oil #2 Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1114: Limit and control secondary combustion air in furnace | $8,107 | $370 | n/a | - | - | - |
$8,107
-
MMBtu
|
- | - |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,666 | $240 | n/a |
$6,810
152,989
kWh
|
$5,608
-
kW-mo/yr
|
$248 | - | - | - |
| 03 | 2.4133: Use most efficient type of electric motors | $3,918 | $8,274 | n/a |
$1,172
26,377
kWh
|
$2,669
-
kW-mo/yr
|
$77 | - | - | - |
| 04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $4,907 | $2,175 | n/a | - | - | - |
$4,907
-
MMBtu
|
- | - |
| 05 | 2.2511: Insulate bare equipment | $880 | $585 | n/a | - | - | - |
$880
-
MMBtu
|
- | - |
| 06 | 2.7132: Install timers on light switches in little used areas | $1,742 | $125 | n/a |
$1,742
38,394
kWh
|
- | - | - | - | - |
| 07 | 3.1171: Change product specs | $5,112 | - | n/a | - | - | - | - | $5,112 | - |
| 08 | 4.111: Add equipment/ operators to reduce production bottleneck | $169,964 | $15,000 | n/a |
$1,967
43,962
kWh
|
- | - | - | - | $167,997 |
| TOTAL RECOMMENDED | $207,296 | $26,769 |
$11,691
261,722
kWh
|
$8,277
-
kW-mo/yr
|
$325 |
$13,894
-
MMBtu
|
$5,112 | $167,997 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Fuel Oil #2 Savings | Administrative Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs