Assessment Year | 2000 |
---|---|
Principal Product | Precision Sheet Metal Parts |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
53,000
ft2
|
Annual Production | 6,000,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,713 | 3,593,494 |
kWh
|
$0.015 |
Electricity Demand | $28,880 | 3,112 |
kW-mo/yr
|
$9.28 |
Electricity Fees | $2,668 | - |
|
- |
Natural Gas | $43,573 | 8,356 |
MMBtu
|
$5.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,375 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,034 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $768 | $1,500 | - | - | - |
$768
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,562 | $22,374 |
$10,533
205,158
kWh
|
$5,909
-
kW-mo/yr
|
$120 | - | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $1,341 | $1,391 |
$117
(-2,931)
kWh
|
- | $(-1.0) |
$1,225
-
MMBtu
|
- | |
04 | 3.6192: Use a less expensive method of waste removal | $704 | - | - | - | - | - | $704 | |
TOTAL RECOMMENDED | $19,375 | $25,265 |
$10,650
202,227
kWh
|
$5,909
-
kW-mo/yr
|
$119 |
$1,993
-
MMBtu
|
$704 | ||
TOTAL IMPLEMENTED | $18,034 | $23,874 |
$10,533
205,158
kWh
|
$5,909
-
kW-mo/yr
|
$120 |
$768
-
MMBtu
|
$704 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs