| Assessment Year | 2024 |
|---|---|
| Principal Product | Wood Shavings |
| NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 16 |
| Plant Area |
308,140
ft2
|
| Annual Production | 5,600
ton
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $49,692 | 1,229,376 |
kWh
|
$0.040 |
| Electricity Demand | $49,893 | 3,933 |
kW-mo/yr
|
$12.69 |
| LPG | $12,405 | 607 |
MMBtu
|
$20.44 |
| Fuel Oil #1 | $4,610 | 181 |
MMBtu
|
$25.47 |
| Wood | $83,000 | 15,323 |
MMBtu
|
$5.42 |
| Other Gas | $18,898 | 699 |
MMBtu
|
$27.04 |
| TOTAL YEARLY COSTS | $218,498 | |||
| RECOMMENDED SAVINGS* | $78,239 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $72,558 | $568,000 |
$41,385
1,023,882
kWh
|
$41,411
-
kW-mo/yr
|
$(-10,238.0) | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,784 | $4,500 |
$3,524
88,100
kWh
|
- | $(-640.0) | $(-100.0) | |
| 03 | 2.7241: Install outside air damper / economizer on hvac unit | $1,003 | $2,741 |
$1,003
25,059
kWh
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $731 | $2,110 |
$276
6,822
kWh
|
$200
-
kW-mo/yr
|
$255 | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $635 | $583 |
$165
4,089
kWh
|
$470
-
kW-mo/yr
|
- | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $332 | $160 |
$332
8,210
kWh
|
- | - | - | |
| 07 | 2.7134: Use photocell controls | $196 | $97 |
$196
4,894
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $78,239 | $578,191 |
$46,881
1,161,056
kWh
|
$42,081
-
kW-mo/yr
|
$(-10,623.0) | $(-100.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs