ITAC Assessment: NL0094
ITAC logo
ITAC Assessment: NL0094
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Wood Shavings
NAICS 321999: All Other Miscellaneous Wood Product Manufacturing
SIC 2499: Wood Products, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 16
Plant Area 308,140
ft2
Annual Production 5,600
ton
Production Hrs. Annual 5,200
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $49,692 1,229,376
kWh
Electricity Demand $49,893 3,933
kW-mo/yr
LPG $12,405 607
MMBtu
Fuel Oil #1 $4,610 181
MMBtu
Wood $83,000 15,323
MMBtu
Other Gas $18,898 699
MMBtu
TOTAL YEARLY COSTS $218,498
RECOMMENDED SAVINGS* $78,239 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat $72,558 $568,000 $41,385
1,023,882
kWh
$41,411
-
kW-mo/yr
$(-10,238.0) -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,784 $4,500 $3,524
88,100
kWh
- $(-640.0) $(-100.0)
03 2.7241: Install outside air damper / economizer on hvac unit $1,003 $2,741 $1,003
25,059
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $731 $2,110 $276
6,822
kWh
$200
-
kW-mo/yr
$255 -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $635 $583 $165
4,089
kWh
$470
-
kW-mo/yr
- -
06 2.4239: Eliminate or reduce compressed air usage $332 $160 $332
8,210
kWh
- - -
07 2.7134: Use photocell controls $196 $97 $196
4,894
kWh
- - -
TOTAL RECOMMENDED $78,239 $578,191 $46,881
1,161,056
kWh
$42,081
-
kW-mo/yr
$(-10,623.0) $(-100.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs