Assessment Year | 2024 |
---|---|
Principal Product | Grain Dryer |
NAICS | 333111: Farm Machinery and Equipment Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
351,000
ft2
|
Annual Production | 200
units
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $93,411 | 1,515,904 |
kWh
|
$0.062 | |
Electricity Demand | $22,219 | 4,130 |
kW-mo/yr
|
$5.38 | |
Electricity Fees | $7,443 | - |
|
- | |
Natural Gas | $75,928 | 9,555 |
MMBtu
|
$7.95 | |
Waste Disposal Costs | |||||
Water Usage | $3,011 | 755 |
Tgal
|
$3.99 | |
Water Disposal | $6,613 | 755 |
Tgal
|
$8.76 | |
TOTAL YEARLY COSTS | $208,625 | ||||
RECOMMENDED SAVINGS* | $28,454 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $23,613 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $10,602 | $19,848 |
$320
5,161
kWh
|
$82
-
kW-mo/yr
|
- | - | $10,200 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,629 | $7,670 |
$6,214
100,130
kWh
|
$1,415
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,382 | $4,500 |
$6,042
97,548
kWh
|
- | $(-560.0) | $(-100.0) | - | |
04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,454 | $1,764 |
$3,454
55,701
kWh
|
- | - | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $822 | $1,190 |
$638
10,293
kWh
|
$184
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $565 | $831 |
$228
3,680
kWh
|
$27
-
kW-mo/yr
|
$310 | - | - | |
TOTAL RECOMMENDED | $28,454 | $35,803 |
$16,896
272,513
kWh
|
$1,708
-
kW-mo/yr
|
$(-250.0) | $(-100.0) | $10,200 | ||
TOTAL IMPLEMENTED | $23,613 | $32,018 |
$12,576
202,839
kWh
|
$1,497
-
kW-mo/yr
|
$(-560.0) | $(-100.0) | $10,200 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs