| Assessment Year | 2018 |
|---|---|
| Principal Product | Steel Casting Parts |
| NAICS | 331513: Steel Foundries (except Investment) |
| SIC | 3325: Steel Foundries, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
100,000
ft2
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 4,500
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $279,022 | 9,000,000 |
kWh
|
$0.031 | |
| Electricity Demand | $393,257 | 38,151 |
kW-mo/yr
|
$10.31 | |
| Electricity Fees | $21,914 | - |
|
- | |
| Natural Gas | $153,703 | 25,475 |
MMBtu
|
$6.03 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,108 | 4,245 |
Tgal
|
$1.91 | |
| Water Disposal | $14,953 | 3,998 |
Tgal
|
$3.74 | |
| TOTAL YEARLY COSTS | $870,957 | ||||
| RECOMMENDED SAVINGS* | $44,992 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $30,580 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,000 | $23,000 |
$14,835
485,000
kWh
|
$8,165
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.2628: Utilize a less expensive cooling method | $9,412 | $32,000 |
$(-1,880.0)
(-60,662)
kWh
|
$(-4,133.0)
-
kW-mo/yr
|
$5,214
-
Tgal
|
$10,211
-
Tgal
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,580 | - |
$8,000
259,000
kWh
|
- | - | - | $(-420.0) | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $5,000 | $6,500 | - | - | - | - | - | $5,000 | |
| TOTAL RECOMMENDED | $44,992 | $61,500 |
$20,955
683,338
kWh
|
$4,032
-
kW-mo/yr
|
$5,214
-
Tgal
|
$10,211
-
Tgal
|
$(-420.0) | $5,000 | ||
| TOTAL IMPLEMENTED | $30,580 | $23,000 |
$22,835
744,000
kWh
|
$8,165
-
kW-mo/yr
|
- | - | $(-420.0) | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs