Assessment Year 2015
Principal Product Upholstered furniture
NAICS 337121: Upholstered Household Furniture Manufacturing
SIC 2512: Wood Household Furniture, Upholstered
Sales Range $10
M
to 50
M
# of Employees 165
Plant Area 150,000
ft2
Annual Production 60,000
pieces
Production Hrs. Annual 2,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $60,266 1,007,794
kWh
Electricity Demand $14,185 3,533
kW-mo/yr
Natural Gas $9,109 1,029
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,008 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,119

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $6,228 $6,494 $4,281
72,566
kWh
$1,947
-
kW-mo/yr
-
02 2.7134: Use photocell controls $253 $600 $132
2,250
kWh
$121
-
kW-mo/yr
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $567 $100 $390
6,610
kWh
$177
-
kW-mo/yr
-
04 2.2437: Recover waste heat from equipment $751 $3,000 - - $751
-
MMBtu
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $384 $100 $264
4,476
kWh
$120
-
kW-mo/yr
-
06 2.4239: Eliminate or reduce compressed air usage $254 $450 $254
4,312
kWh
- -
07 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $571 $2,500 $392
6,650
kWh
$179
-
kW-mo/yr
-
TOTAL RECOMMENDED $9,008 $13,244 $5,713
96,864
kWh
$2,544
-
kW-mo/yr
$751
-
MMBtu
TOTAL IMPLEMENTED $7,119 $7,644 $4,931
83,604
kWh
$2,188
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs