| Assessment Year | 2000 |
|---|---|
| Principal Product | Cotton/polyester yarn |
| NAICS |
n/a
|
| SIC | 2281: Yarn Spinning Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
200,000
ft2
|
| Annual Production | 28,600,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,142,058 | 32,594,373 |
kWh
|
$0.035 |
| Electricity Demand | $469,944 | 52,913 |
kW-mo/yr
|
$8.88 |
| Electricity Fees | $(-68,603.0) | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $76,462 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $20,439 | $27,000 | n/a |
$17,739
657,093
kWh
|
$2,700
-
kW-mo/yr
|
- | - |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,705 | $51,300 | n/a |
$6,372
236,225
kWh
|
$2,333
-
kW-mo/yr
|
- | - |
| 03 | 2.2625: Chill water to the highest temperature possible | $921 | $1,000 | n/a |
$508
18,757
kWh
|
$813
-
kW-mo/yr
|
- | $(-400.0) |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $30,871 | $10,600 | n/a |
$22,611
837,632
kWh
|
$8,260
-
kW-mo/yr
|
- | - |
| 05 | 3.4155: Meter waste water | $15,526 | $7,025 | n/a | - | - |
$15,526
-
Tgal
|
- |
| TOTAL RECOMMENDED | $76,462 | $96,925 |
$47,230
1,749,707
kWh
|
$14,106
-
kW-mo/yr
|
$15,526
-
Tgal
|
$(-400.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs