ITAC Assessment: NC0066
ITAC logo
ITAC Assessment: NC0066
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Thermoformed Plastic
NAICS
n/a
SIC 3080:
Sales Range $1
M
to 5
M
# of Employees 50
Plant Area 54,500
ft2
Annual Production 75,000,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $107,676 1,582,943
kWh
Natural Gas $5,555 950
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,543 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,599

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,066 $260 $1,066
17,878
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $112 $330 $112
2,052
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $229 $1,120 $229
4,103
kWh
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $487 $330 $487
8,499
kWh
05 2.4133: Use most efficient type of electric motors $188 $198 $188
3,224
kWh
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,500 - $2,500
-
kWh
07 2.7232: Replace existing hvac unit with high efficiency model $10,368 $30,845 $10,368
117,526
kWh
08 2.7425: Clean or color roof to reduce solar load $1,705 $1,806 $1,705
21,395
kWh
09 2.2511: Insulate bare equipment $1,888 $500 $1,888
32,825
kWh
TOTAL RECOMMENDED $18,543 $35,389 $18,543
207,502
kWh
TOTAL IMPLEMENTED $3,599 $3,846 $3,599
53,927
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs