Assessment Year | 1995 |
---|---|
Principal Product | Thermoformed Plastic |
NAICS |
n/a
|
SIC | 3080: |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
54,500
ft2
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,676 | 1,582,943 |
kWh
|
$0.068 |
Natural Gas | $5,555 | 950 |
MMBtu
|
$5.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,543 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,599 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,066 | $260 |
$1,066
17,878
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $112 | $330 |
$112
2,052
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $229 | $1,120 |
$229
4,103
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $487 | $330 |
$487
8,499
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $188 | $198 |
$188
3,224
kWh
|
|
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,500 | - |
$2,500
-
kWh
|
|
07 | 2.7232: Replace existing hvac unit with high efficiency model | $10,368 | $30,845 |
$10,368
117,526
kWh
|
|
08 | 2.7425: Clean or color roof to reduce solar load | $1,705 | $1,806 |
$1,705
21,395
kWh
|
|
09 | 2.2511: Insulate bare equipment | $1,888 | $500 |
$1,888
32,825
kWh
|
|
TOTAL RECOMMENDED | $18,543 | $35,389 |
$18,543
207,502
kWh
|
||
TOTAL IMPLEMENTED | $3,599 | $3,846 |
$3,599
53,927
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs